A-A-52199
5.6.3.2 Rim warpage test. The sample unit for this test shall be three (3) trays. Rim warpage shall be determined by placing the tray upside down on a flat surface and holding it firmly in place by a 10 pound weight with a diameter not exceeding 5 inches positioned at the center of the tray. At this time, measure the distance between the tray rim and the flat surface around the tray’s perimeter. The distance, when measured with a feeler gauge, shall be no greater than that specified in 3.6 anywhere around its perimeter. Any test failure shall be cause for rejection of the lot.
6. PACKAGING
6.1 Packaging, packing and marking. Packaging, packing, and marking shall be in accordance with the requirements of ASTM D 3951, unless otherwise specified in the contract or purchase order (see 7.1).
7. NOTES
7.1 Acquisition requirements. Acquisition documents must specify the following:
a. Title, number and date of this document.
b. Type and class required (see 2.1).
c. Color required (see 3.7).
d. Packaging requirements (see 6.1).
7.2 Sources for documents.
7.2.1 Sources for non-Government association documents.
ASTM
D 704 – Melamine-Formaldehyde Molding Compounds
D 3951 – Standard Practice for Commercial Packaging
E 380 – Use of the International System of Units (SI) (The Modernized Metric System)